Jump to content

M2M1

Easy Integration of RS-485 Devices with Danfoss Systems

  • Easy Installation
    Plug-and-play functionality reduces installation and integration time.
  • Flexible Platform
    Different software variants enable integration with a wide range of third-party devices
  • Industrial-Grade Reliability
    Designed for reliable operation in refrigeration, HVAC and automation systems.
  • Future-Ready Solution
    New integrations can be developed using our configuration tool.

Smart Communication Gateway for Easy System Integration

M2M1 is a smart communication gateway that enables third-party devices to be integrated with Danfoss System Managers. By emulating a compatible Danfoss device, external controllers and sensors can be connected quickly without the need for complex custom development.

The Challenge

Danfoss System Managers are designed to communicate with Danfoss controllers.
Third-party devices using RS-485/Modbus RTU often use different data structures and register maps, which means that the System Manager normally cannot identify or communicate with these devices directly.

Traditional integration therefore requires:

  • Custom protocol gateway
  • Customized register maps
  • Manual configuration during commissioning

Without an integration solution such as M2M1, there is effectively no standardized way to connect third-party devices to Danfoss systems.

The result is longer installation times, higher costs and an increased risk of communication issues in critical systems.

The Solution

M2M1 creates a standardized and reliable communication link between third-party devices and Danfoss controllers.
By presenting the connected device as an EKC-compatible Danfoss controller, integration becomes possible even where native support is otherwise unavailable.

This means:

  • Integration without custom development
  • The Danfoss system can identify and read the connected device
  • Installation becomes predictable and traceable
  • Existing Modbus addresses can be reused
  • Devices can be identified automatically during commissioning

Software

  • M2M1-10
    Panasonic CO₂ condensing units

    Panasonic OCU-CR200/1000 CO₂ condensing units → AK-SM 350/720/800/800A

    1x unit per M2M1

  • M2M1-30
    StrongPoint Click&Collect

    StrongPoint Click&Collect MCX controllers → AK-SM 350/720

    10x unit per M2M1

  • M2M1-40
    Woodley 3rd party bus

    Danfoss new generation GD → Woodley 3rd party bus (AK-SM 350)

    1x unit per M2M1

  • M2M1-50
    Emerson ECB-PRO

    Emerson ECB-PRO → AK-SM 350/720/800/800A

    4x units per M2M1

  • M2M1-51
    Carel BLDC

    Space Engineering BLDC Rotary Pack → AK-SM 800/800A

    1x unit per M2M1

  • M2M1-53
    Dixell XM679K v4.2

    Dixell XM679K v4.2 → AK-SM 800/800A

    3x units per M2M1

  • M2M1-54
    Dixell XM679K v5.4

    Dixell XM679K v5.4 → AK-SM 800/800A

    3x units per M2M1

  • M2M1-55
    Eliwell EVO V910

    Eliwell EVO V910 → AK-SM 800/800A

    1x unit per M2M1

  • M2M1-56
    Eliwell EWSense

    Eliwell EWSense → AK-SM 800/800A

    1x unit per M2M1

  • M2M1-57
    MYPRO TOUCH+

    MYPRO TOUCH+ → AK-SM 800/800A

    1x unit per M2M1

  • M2M1-58
    FRICO SIRe

    FRICO SIRe → AK-SM 800/800A

    1x unit per M2M1

  • M2M1-59
    AF-ENERGY NINO 3R-A

    AF-ENERGY NINO 3R-A → AK-SM 800/800A

    5x units per M2M1

  • M2M1-60
    Lennox CLIMATIC 60

    Lennox CLIMATIC 60 → AK-SM 800/800A

    1x unit per M2M1

  • M2M1-62
    Ciatesa ALDI controller

    Ciatesa ALDI controller v1.3 → AK-SM 800/800A

    1x unit per M2M1

  • M2M1-63
    Produal HDU CO₂ sensors

    Produal HDU CO₂ sensors → AK-SM 800/800A

    10x units per M2M1

  • M2M1-64
    NovoCon Digital Actuator

    NovoCon Digital Actuator → AK-SM 800/800A

    32x units per M2M1

  • M2M1-65
    SonoMeter 40

    SonoMeter 40 → AK-SM 800/800A

    32x units per M2M1

  • M2M1-67
    Danfoss EKE 1C x1

    Danfoss EKE 1C x1 → AK-SM 720

    1x unit per M2M1

  • M2M1-68
    Danfoss EKE 1C x2

    Danfoss EKE 1C x2 → AK-SM 720

    1x unit per M2M1

Technical Specifications

Protocols

  • Modbus RTU (standard)
  • Other RS-485-based protocols can be implemented on request

Interfaces

  • 2 x RS-485

Power Supply

  • 12–24 V DC
  • < 1 W power consumption

Mechanical

  • Dimensions: 35 × 90 × 32 mm
  • Plastic enclosure
  • DIN rail mounting
  • IP20
  • CE, RoHS

Network & Interfaces

  • 1 × Ethernet-port
  • 1 x CANbus
  • 2 x RS-485
  • Web GUI via WiFi or Ethernet

Features

RS-485 Communication Gateway
Connects third-party devices directly to a Danfoss System Manager.

Danfoss Device Emulation
Enables external devices to operate as standard Danfoss controllers within the system.

Software-Based Integrations
Different software variants support specific devices and applications.

Support for Multiple Devices
Depending on the software, multiple devices can be connected to a single M2M1.

Customizable Software
New integrations can be created using our configuration tool or with support from our developers.

Typical Applications

M2M1 is designed for applications where third-party devices need to be integrated with a Danfoss monitoring system.

Typical applications include:

  • Refrigeration and freezer systems
  • HVAC systems
  • CO₂ condensing units
  • Energy meters and sensors
  • Industrial control systems
  • Upgrades to existing installations

M2M1 is compatible with several Danfoss System Managers, including AK-SM 350, AK-SM 720, AK-SM 800 and AK-SM 800A.

Business Benefits

Faster Integration – Shorter installation times and less manual configuration.

Greater System Compatibility –Enables a wider range of third-party devices to be integrated.

Extended Service Life of Existing Systems – New devices can be connected without replacing the Danfoss System Manager.

Reduced Project Risk – Proven software solutions provide reliable communication.

More Business Opportunities – Enables solutions that would otherwise require custom development.

Support & Remote Access

Technical Support

We can support you throughout the entire integration process – from selecting the appropriate firmware to the completed installation.

We provide:

  • Selection of the appropriate software for the application

  • Technical guidance during integration

  • Commissioning or troubleshooting by our technicians (charged separately)

  • Development of customized solutions (charged separately)

You get access to technicians with in-depth knowledge of both Danfoss System Managers and integration environments.

For advanced integrations, new software solutions can be developed using our M2M1 Tool, which enables custom integrations to be created for new devices.

Need Support from Our Development Team?

Do you have questions about our products, Alsmart, integration solutions or control systems?

Fill in the form and we’ll get in touch.

    * Required field

    Consent